Provider · Orders · WO-4401
WO-4401.
AMS–FRA · 40G · Lumen Bay Power. Stage testing · 92% SLA runway.
Stage ladder
design → loa → provisioning → testing → lit- designdone1d 8h
- loadone2d 3hLOA countersigned by facility.
- provisioningdone5d 8h
- testingactivecurrent69d 22hAcceptance tests running; one check pending turn-up.
- litpendingpending
The per-stage clock ticks live for the active stage and freezes when prefers-reduced-motion is set. The SLA runway below reflects the whole order against its turn-up target.
92% SLA runway
Validation suite
pre-handoff · simulatedPre-handoff validation
Layer 1: pre-handoff optics
3/3 pass- TX powerTransmit power within spec (-1 to +1 dBm).0.2 dBmpass
- RX powerReceive power above the sensitivity floor.-3.4 dBmpass
- Loss of signalNo LOS alarms on either end.pass
Layer 2: transport stability
2/2 pass- Link stabilityNo interface flaps over the 30-minute window.pass
- FCS errorsFrame check sequence error rate under threshold.0 errpass
Layer 3: RFC / protocol compliance
2/2 pass- BGP sessionBGP peering established and stable.pass
- Route propagationExpected prefixes learned on both ends.128 prefixespass
Service: BERT / throughput / failover
2/3 pass · 1 pending- Latency SLARound-trip latency within the SLA target.4.1 mspass
- ThroughputSustained throughput at the ordered rate.39.8 Gbpspass
- FailoverPath failover under primary loss.Failover validation scheduled at the turn-up window.pending
Configuration diff: delivered vs ordered
simulated · previewConfiguration diff between delivered and ordered interface config.5 line(s) added, 1 line(s) removed.
interface et-0/0/0 { description "MIA-PHX backhaul"; mtu 9192;
Added:
unit 0 {
Added:
family inet {
Added:
address 10.50.12.1/31;
Added:
}
Added:
}
Removed:
mtu 9000;
enable;}
Provisioning feed
newest at bottom · no auto-scroll- Jul 25, 08:00ZtestingAcceptance test suite started.
- Jul 25, 09:10ZtestingLayer 1 optics: PASS (TX/RX within spec).
- Jul 25, 10:30ZtestingLatency 4.1 ms, throughput 39.8 Gbps: PASS.
- Jul 25, 10:31ZtestingFailover validation pending the turn-up window.